FCom Fuji Crystal · FSF-5050 Series
246 & 250 MHz SAW Filters
FSF-5050-246M · FSF-5050-250M
Two VHF / IF SAW filters in a 5.0 × 5.0 mm, 8-pad SMD package. Compare the narrow-band 246M with external matching and the 250M with its specified passband and 50 Ω test terminations.
- 5.0 × 5.0 mm
- 8-pad SMD
- Model-specific matching
Choose by frequency and interface
Two models with distinct design requirements
Select the required frequency, then compare bandwidth definitions, matching conditions and operating limits.
FSF-5050-246M
246 MHz
External matching required
- 1 dB bandwidth
- 200 kHz min. / 350 kHz typ.
- 3 dB bandwidth
- 0.5 MHz typ.
- ILmin, real matching
- 2.1 dB typ. / 3.4 dB max.
- Operating temperature
- −20 to +70 °C
FSF-5050-250M
250 MHz
50 Ω source/load test terminations
- Specified passband
- 249.9–250.9 MHz
- 3 dB bandwidth
- Not specified
- Passband insertion loss
- 2.05 dB typ. / 3.8 dB max.
- Operating temperature
- −40 to +85 °C
246M minimum insertion loss and 250M passband insertion loss describe different conditions. Compare each model against its own specification; a shared package does not make the filters interchangeable.
Model-specific electrical data
Electrical specifications
Min., Typ. and Max. values retain their stated classifications. Values spanning those columns have no such classification in the datasheet. “—” means not specified. Scroll each table horizontally on smaller screens.
FSF-5050-246M
| Parameter | Min. | Typ. | Max. | Unit | Definition / condition |
|---|---|---|---|---|---|
| Center frequency | 246.0 | MHz | Stated value; not classified as Min., Typ. or Max. | ||
| 1 dB bandwidth | 200 | 350 | — | kHz | Ideal matching; retain the 1 dB bandwidth definition. |
| 3 dB bandwidth | — | 0.5 | — | MHz | Ideal matching; no minimum or maximum is specified. |
| Minimum insertion loss, ILmin — real matching | — | 2.1 | 3.4 | dB | Includes losses in real matching components. |
| Minimum insertion loss, ILmin — ideal matching | — | 1.9 | 3.2 | dB | Ideal simulated matching; excludes matching-element losses. |
| Passband relative to ILmin | — | 0.5 | 1.5 | dB | 245.9–246.1 MHz; ideal simulated matching. Not specified as amplitude ripple. |
| Stopband attenuation | 50 | 65 | — | dB | 10–203 MHz; relative to ILmin, ideal matching. |
| Stopband attenuation | 33 | 41 | — | dB | 203–240 MHz; relative to ILmin, ideal matching. |
| Stopband attenuation | 15 | 25 | — | dB | 240–245 MHz; relative to ILmin, ideal matching. |
| Stopband attenuation | 10 | 18 | — | dB | 247–265 MHz; relative to ILmin, ideal matching. |
| Stopband attenuation | 39 | 47 | — | dB | 265–400 MHz; relative to ILmin, ideal matching. |
| Stopband attenuation | 50 | 57 | — | dB | 400–1000 MHz; relative to ILmin, ideal matching. |
| Operating temperature | −20 | — | +70 | °C | Operating limits. |
| Storage temperature | −40 | — | +85 | °C | Storage limits; separate from the operating range. |
| Maximum RF input power | — | — | 10 | dBm | Maximum rating. |
| Maximum DC voltage | — | — | 0 | V | Maximum rating. |
| Temperature coefficient | −0.036 | ppm/°C² | Stated coefficient; no Min./Typ./Max. classification is given. | ||
| Input impedance at Fc | 2195 Ω ∥ 1.9 pF | — | Ideal-match model. | ||
| Output impedance at Fc | 2915 Ω ∥ 1.68 pF | — | Ideal-match model. | ||
| Source / load test termination | 50 / 50 | Ω | External matching required; not the device-port impedances. | ||
Bandwidth and attenuation values use ideal matching. The 245.9–246.1 MHz passband row is relative to ILmin, not an amplitude-ripple specification. Do not combine ideal-match relative values with real-match ILmin to infer an unqualified passband-loss limit.
FSF-5050-250M
| Parameter | Min. | Typ. | Max. | Unit | Definition / condition |
|---|---|---|---|---|---|
| Center frequency | 250.0 | MHz | Stated value; not classified as Min., Typ. or Max. | ||
| Specified passband | 249.9–250.9 | MHz | Interval for insertion loss and amplitude ripple. | ||
| 3 dB bandwidth | Not specified | — | The 1 MHz specified passband span is not a 3 dB bandwidth. | ||
| Insertion loss | — | 2.05 | 3.8 | dB | 249.9–250.9 MHz; 50 Ω source/load test terminations. |
| Amplitude ripple | — | 0.13 | 1.8 | dB | 249.9–250.9 MHz. |
| Stopband attenuation | 45 | 66 | — | dB | 150–210 MHz; referenced to 0 dB. |
| Stopband attenuation | 43 | 58 | — | dB | 290–650 MHz; referenced to 0 dB. |
| Stopband attenuation | 40 | 63 | — | dB | 650–700 MHz; referenced to 0 dB. |
| Operating temperature | −40 | — | +85 | °C | Operating limits. |
| Storage temperature | −40 | — | +85 | °C | Storage limits. |
| Maximum RF input power | — | — | 10 | dBm | Maximum rating. |
| Maximum DC voltage | — | — | 5 | V | Maximum rating. |
| Source / load test termination | 50 / 50 | Ω | Direct test connection; verify the actual system interface. | ||
The specified 249.9–250.9 MHz interval is not symmetric about 250 MHz. Its 1 MHz span is not a 3 dB bandwidth. Stopband attenuation is referenced to 0 dB.
The model datasheets do not state an electrical-characteristic test temperature. Operating ranges do not turn typical values into guaranteed limits across the full range. Maximum ratings are limits, not recommended operating targets.
Typical applications
VHF signal selection and IF filtering
VHF receiver filtering
Choose the center frequency and bandwidth that accommodate the wanted signal.
RF front-end selection
Check blocker rejection in the listed attenuation bands, with the applicable matching conditions.
Superheterodyne IF stages
Evaluate insertion loss and the interface to the preceding and following IF stages.
Design-in essentials
Match the interface to the selected model
246M: external matching
The ideal-match model gives 2195 Ω ∥ 1.9 pF input impedance and 2915 Ω ∥ 1.68 pF output impedance at Fc. The 50 Ω test terminations do not describe these device-port impedances.
The ideal simulation uses 212 nH series inductance at the input, 245 nH at the output and 0 pF shunt capacitance at each port. These values are simulation conditions, not a finalized production component list.
The datasheet identifies Coilcraft 0805 CS inductors and Murata 0402 GRM capacitors for real matching components. Verify component values, losses and PCB parasitics for the intended design.
Observe the 10 dBm maximum RF input and 0 V maximum DC voltage.
250M: 50 Ω test interface
The datasheet uses 50 Ω source and load terminations with a direct test connection. Confirm the response with the actual source, load and PCB implementation.
Apply the insertion-loss and ripple limits over 249.9–250.9 MHz. Use the 0 dB-referenced attenuation limits at the relevant blocker frequencies.
Observe the 10 dBm maximum RF input and 5 V maximum DC voltage.
Shared mechanical format
Package & pin assignment
5.0 × 5.0 mm · 1.5 mm maximum height · 8-pad SMD
Both model drawings use the pin functions shown here. Confirm pad orientation and signal-port assignment from the applicable drawing before PCB release, especially for the unequal 246M input and output matching requirements.
For other pin configurations, contact FCom.
| Pin(s) | Function |
|---|---|
| 2 | Input / Output |
| 6 | Input / Output |
| 1, 3, 5, 7 | Ground |
| 4, 8 | Case Ground |
Both signal pins are labeled Input/Output in the drawings. This does not establish identical port impedances or interchangeable matching networks.
Selection and design-in support
Share your signal and interface requirements
Include the selected model, required bandwidth and definition, source/load requirements, operating temperature, blocker frequencies and rejection targets. For 246M, describe the matching approach and PCB conditions.
Add sample quantity and estimated usage. Confirm the applicable specification, signal-port orientation and complete ordering code with FCom before ordering.
Engineering questions
Frequently asked questions
How should I choose between 246M and 250M?
Compare the required frequency, bandwidth definition, attenuation bands, matching and temperature limits. FSF-5050-246M requires external matching; FSF-5050-250M uses 50 Ω source/load test terminations. The common package does not establish interchangeability.
Is FSF-5050-246M a directly matched 50 Ω filter?
No. The specified 50 Ω values are test source and load terminations. External matching is required. At Fc, the ideal-match model gives 2195 Ω ∥ 1.9 pF at the input and 2915 Ω ∥ 1.68 pF at the output.
Why are two insertion-loss values listed for 246M?
Real-match ILmin is 2.1 dB typical and 3.4 dB maximum, including matching-component losses. Ideal-match ILmin is 1.9 dB typical and 3.2 dB maximum, excluding those losses. Passband and stopband values relative to ILmin use ideal simulated matching; keep these conditions separate.
Does FSF-5050-250M have a 1 MHz 3 dB bandwidth?
No 3 dB bandwidth is specified. The 249.9–250.9 MHz interval is the specified passband for insertion loss and amplitude ripple. Its 1 MHz span and its asymmetric position around the stated 250 MHz center frequency must be retained as specified.
Do both models have the same temperature and input limits?
Both specify 10 dBm maximum RF input and −40 to +85 °C storage. Operating limits are −20 to +70 °C for 246M and −40 to +85 °C for 250M. Maximum DC voltage is 0 V for 246M and 5 V for 250M. Maximum ratings are not recommended operating targets.
What information should I provide for design support?
Provide the model or center frequency, bandwidth definition, source/load requirements, temperature range, blocker frequencies, rejection targets, sample quantity and estimated usage. For 246M, include the matching network and PCB conditions. Confirm signal-port orientation and the complete ordering code with FCom.