How to Choose an Audio Clock Frequency for 44.1 kHz and 48 kHz Systems

Audio clock frequency guide for 44.1 kHz and 48 kHz systems, illustrated with crystal oscillators and a clock waveform.

Audio Clock Design Guide

How to Choose an Audio Clock Frequency for 44.1 kHz and 48 kHz Systems

Choose an audio clock frequency by identifying the sampling-rate family, checking the clock ratios supported by the receiving IC, and confirming the electrical and timing requirements of the complete clock path.

For example, 22.5792 MHz corresponds to 512 times a 44.1 kHz sampling rate, while 24.576 MHz corresponds to 512 times a 48 kHz sampling rate. Frequencies such as 45.1584 MHz and 49.152 MHz provide additional division options when the system architecture supports them.

This guide explains the frequency relationships and a practical selection process for audio DACs, ADCs, codecs, and processors. Each device’s datasheet determines which clock configurations are supported.

1. Identify the Audio Sampling-Rate Family

Start by listing every sampling rate the product must support. Many audio designs operate within one or both of the following families:

Examples of sampling rates within each family
Sampling-rate family Example sampling rates
44.1 kHz family 44.1, 88.2, 176.4, and 352.8 kHz
48 kHz family 48, 96, 192, and 384 kHz

The listed rates within each family are related by factors of two. Suitable integer dividers can therefore derive several sample timings from one reference frequency.

Supporting both families requires additional planning. A 24.576 MHz reference cannot generate exactly 44.1 kHz through integer division alone. A system may use selectable references or suitable programmable clock synthesis to provide the required frequencies.

2. Understand MCLK, BCLK, and LRCLK

Audio interfaces use clocks with different functions. Identify the signal at each pin before selecting an oscillator.

Clock functions in a conventional stereo I2S system
Clock Function
LRCLK / WS Identifies the left and right channels. One complete cycle corresponds to one stereo sample frame.
BCLK / BCK Clocks the serial audio data between devices.
MCLK / system clock Provides a reference for internal processing and conversion circuitry where required. It is separate from the basic three-wire I2S bus.

For the serial clock, word-select, and data definitions, refer to the NXP I2S Bus Specification (PDF).

For a conventional stereo interface, calculate the bit clock using the configured slot width:

BCLK = sampling rate × 2 channels × bits per channel slot

At 48 kHz with two 32-bit slots, BCLK is 48,000 × 2 × 32 = 3.072 MHz. A 24-bit audio sample can occupy a 32-bit slot, so use the actual interface configuration when calculating BCLK.

An external MCLK is device dependent. For example, the TI PCM5102A datasheet (PDF) describes a mode that generates internal system clocks from BCK using an integrated PLL, subject to its specified clock and startup conditions.

Pin names vary between manufacturers: NXP uses SCK for the serial bit clock, while some converter datasheets use SCK for a separate system clock. Check each pin’s definition.

3. Calculate the Required Master Clock Frequency

When the receiving device specifies its master clock as a multiple of the sampling rate, use:

MCLK = fs × N

Here, fs is the sampling rate and N is a ratio supported by the device in the selected operating mode.

Calculated frequency relationships; verify device compatibility separately
MCLK-to-fs ratio At 44.1 kHz At 48 kHz
128fs 5.6448 MHz 6.144 MHz
192fs 8.4672 MHz 9.216 MHz
256fs 11.2896 MHz 12.288 MHz
384fs 16.9344 MHz 18.432 MHz
512fs 22.5792 MHz 24.576 MHz
768fs 33.8688 MHz 36.864 MHz
1024fs 45.1584 MHz 49.152 MHz
2048fs 90.3168 MHz 98.304 MHz

For a device-specific example, the TI PCM1792A datasheet (PDF) lists 128fs, 192fs, 256fs, 384fs, 512fs, and 768fs system-clock ratios. Its clock table includes sampling-rate and control-mode restrictions. Read the table and its footnotes when selecting a frequency.

4. Compare the Main Audio Clock Frequency Pairs

22.5792 MHz and 24.576 MHz

These frequencies correspond to 512fs at the two base sampling rates:

  • 22.5792 MHz = 44.1 kHz × 512
  • 24.576 MHz = 48 kHz × 512

They are useful starting points when the converter accepts these frequencies and ratios. As the sampling rate increases, the ratio decreases: 24.576 MHz corresponds to 256fs at 96 kHz and 128fs at 192 kHz.

45.1584 MHz and 49.152 MHz

This pair provides the following calculated relationships across higher sampling rates:

Calculated ratios using 45.1584 MHz for the 44.1 kHz family and 49.152 MHz for the 48 kHz family
44.1 kHz family 48 kHz family MCLK-to-fs ratio
44.1 kHz 48 kHz 1024fs
88.2 kHz 96 kHz 512fs
176.4 kHz 192 kHz 256fs
352.8 kHz 384 kHz 128fs

Check whether the selected frequency can feed the converter directly or must first pass through a suitable divider or synthesizer. For example, dividing 49.152 MHz by two produces 24.576 MHz.

90.3168 MHz and 98.304 MHz

These frequencies correspond to 2048fs at 44.1 kHz and 48 kHz respectively. They may serve as upstream references where the clock architecture needs additional division options. Dividing by four produces 22.5792 MHz and 24.576 MHz.

Confirm the input limits and output capabilities of the intervening clock circuitry. Select these references according to the clock tree’s requirements and evaluate routing, loading, power consumption, and emissions.

For frequency-specific component options, explore FCom audio clock crystals and oscillators covering 22.5792, 24.576, 45.1584, 49.152, 90.3168, and 98.304 MHz. Compare the active oscillator and passive crystal options, then confirm the component type and configuration required by your circuit.

For oscillator selection by package, supply voltage, and output format, explore the FCom crystal oscillator range .

5. Work Through a Practical Selection Example

The TI PCM1792A system-clock table linked above provides a concrete example: it lists a 24.576 MHz reference at 48, 96, and 192 kHz. For a stereo interface configured with two 32-bit slots, the clock relationships are:

PCM1792A MCLK combinations and calculated BCLK for two 32-bit slots
Sampling rate MCLK MCLK-to-fs ratio BCLK at 64fs
48 kHz 24.576 MHz 512fs 3.072 MHz
96 kHz 24.576 MHz 256fs 6.144 MHz
192 kHz 24.576 MHz 128fs 12.288 MHz

A 24.576 MHz oscillator can provide the reference for these PCM1792A operating points. The audio controller or clock circuitry must generate the required BCLK and LRCLK while satisfying the converter’s synchronization requirements.

If the product also supports 44.1, 88.2, and 176.4 kHz, evaluate a 22.5792 MHz reference with the corresponding 512fs, 256fs, and 128fs ratios. Confirm support for every intended operating point.

Where synchronous clocks are required, derive them from a common reference or use an appropriate locking architecture. Independently running oscillators at nominally related frequencies can drift relative to one another.

6. Check Clock Quality and Electrical Compatibility

After selecting a nominal frequency, review the oscillator specification and the complete path to the receiving IC.

Parameters to confirm before selecting an audio clock oscillator
Parameter What to check
Frequency accuracy and stability Initial tolerance, temperature variation, aging, and the system’s timing requirements.
Phase noise The spectrum across relevant offset frequencies and the effects of the clock architecture.
RMS phase jitter Integration limits, measurement conditions, and contributions from the complete clock path.
Output compatibility Logic levels, oscillator supply voltage, receiver thresholds, and input loading.
Clock waveform Duty cycle, rise and fall times, and the receiving device’s timing limits.
Physical and control requirements Package size, pin assignment, operating temperature, startup time, and enable behavior.

Choose the Correct Audio Clock Device

An active crystal oscillator requires a power supply and generates a clock output. A passive quartz crystal is a resonator that operates with a compatible oscillator circuit. These components have different interfaces; a matching nominal frequency does not make them interchangeable.

For an external clock input, select an audio clock oscillator with compatible output levels and loading. If the IC instead specifies a crystal interface, follow its crystal requirements, including load capacitance, ESR, and drive level. Use the IC’s documented external-clock mode when driving a pin that also supports a crystal connection.

Distinguish Frequency Accuracy from Jitter

Frequency accuracy concerns the average frequency relative to its nominal value and is often expressed in ppm. Jitter describes variations in clock-edge timing. Evaluate both according to the system’s requirements.

Compare Jitter Under Consistent Conditions

RMS phase jitter calculated from phase noise depends on the integration bandwidth. Compare specifications using consistent limits and measurement conditions, and review the phase-noise spectrum where relevant.

Analog Devices explains the measurement relationship in Clock (CLK) Jitter and Phase Noise Conversion.

For a closer look at specification comparisons, read the FCom phase noise vs. jitter guide.

Evaluate the delivered clock at the receiver as well as the oscillator output. Supply noise, buffers, dividers, PLLs, and PCB routing can affect the final signal. Validate the completed design using the electrical and audio-performance measurements appropriate to the application.

7. Support Both Sampling-Rate Families

A product supporting both families may use a selectable pair such as 22.5792 / 24.576 MHz or 45.1584 / 49.152 MHz. Suitable programmable clock generation is another option.

Compare the supported frequencies, output quality, power consumption, startup behavior, and switching requirements of each approach. With separate oscillators, use suitable clock selection circuitry and coordinate output enables according to the design.

When changing sampling rates, follow the converter’s requirements for muting, reset, clock stabilization, interface configuration, and relocking before resuming audio.

Frequently Asked Questions

Is 24.576 MHz suitable for every 48 kHz audio system?

24.576 MHz equals 512fs at 48 kHz. Suitability depends on the receiving device’s supported ratios, input limits, and clock configuration. Some devices use other references or generate system clocks internally.

Can I replace 22.5792 MHz with 24.576 MHz?

A direct replacement changes the clock-to-sampling-rate relationship. Supporting the new frequency requires a compatible device configuration and clock architecture. Check the complete timing plan before changing the oscillator.

Can 49.152 MHz be used in a 48 kHz system?

49.152 MHz equals 1024fs at 48 kHz. It can be used directly when the device supports that combination, or as an upstream reference with suitable clock division or synthesis.

Does a higher clock frequency improve audio performance?

A higher reference frequency provides different division options. Audio performance also depends on clock quality, converter architecture, power supplies, and implementation. Choose the frequency that meets the timing plan and validate performance in the finished design.

Do all audio DACs require an external master clock?

Some DACs require an external reference, while others can generate their internal clocks from the serial interface. Check the selected DAC’s clocking modes and their operating conditions.

Find an Audio Clock for Your Design

Share your sampling rates, DAC or ADC part number, required reference frequency, supply voltage, output format, package size, and phase-noise or jitter requirements with FCom.

Our team can review the requirements and discuss suitable crystal oscillator options, datasheets, and evaluation samples for your audio design.

Share:

Suggested Content:

Drag & Drop Files, Choose Files to Upload

Contact Us Anytime

Drag & Drop Files, Choose Files to Upload

Contact Us Anytime

Drag & Drop Files, Choose Files to Upload