FSF-5050 Series · Narrowband RF SAW Filters
862.5–869.6 MHz Narrowband SAW Filters
FSF-5050-862M5 · FSF-5050-868M3 · FSF-5050-868M69 · FSF-5050-868M95 · FSF-5050-869M6
Compare five separate frequency options for narrowband UHF signal selection, receiver preselection and RF test paths in a 5.0 × 5.0 mm surface-mount package.
- Five center frequencies
- 5.0 × 5.0 mm SMD
- −45 to +90 °C operation
Key Features
Select the Frequency and Bandwidth for Your Signal
Five Frequency Options
862.5–869.6 MHz
Discrete center frequencies: 862.5, 868.3, 868.69, 868.95 and 869.6 MHz. The listed range is not one continuous passband.
Narrowband Selectivity
1.50–1.90 MHz typ.
Model-specific 3 dB bandwidth relative to ILmin. Only FSF-5050-862M5 also lists a minimum BW3: 1.00 MHz.
Insertion Loss
2.7–3.3 dB typ.
Typical minimum insertion loss across the five models. Maximum limits and ILmin frequency intervals differ by model.
Electrical Specifications
Compare the Five Models
BW3 is defined relative to minimum insertion loss (ILmin). The ILmin interval below is a separate specification and must not be substituted for the 3 dB bandwidth.
| Model | Center frequency Typ. |
BW3 Min. |
BW3 Typ. |
ILmin (dB) Typ. / Max. |
ILmin interval |
|---|---|---|---|---|---|
| FSF-5050-862M5 | 862.5 | 1.00 | 1.70 | 3.2 / 4.5 | 862.25–862.75 |
| FSF-5050-868M3 | 868.3 | — | 1.50 | 2.7 / 4.2 | 868.00–868.78 |
| FSF-5050-868M69 | 868.69 | — | 1.90 | 3.3 / 4.7 | 868.00–869.38 |
| FSF-5050-868M95 | 868.95 | — | 1.85 | 3.0 / 4.7 | 868.7–869.2 |
| FSF-5050-869M6 | 869.6 | — | 1.85 | 3.0 / 4.7 | 869.2–870.18 |
— = not specified. No maximum BW3 is listed for these models. Amplitude ripple is not separately specified. Typical values are for design guidance; confirm final production limits for the selected model.
All five models list an operating range of −45 to +90 °C and storage limits of −45 °C minimum / +90 °C maximum. These limits do not define a common electrical measurement temperature; see the model-specific reference conditions below.
Typical Applications
Narrowband UHF Filtering
UHF Signal Selection
Evaluate the center frequency and bandwidth against the wanted signal, frequency tolerance and receiver channel plan.
Receiver Preselection
Use model-specific response data to assess out-of-band blockers, insertion loss and the complete receiver sensitivity budget.
RF Test & Measurement
Provide frequency-selective filtering in a measurement path, accounting for matching, interconnect loss and fixture response.
Integration Notes
Use the Matching Network for the Selected Model
The documented setup uses a 50 Ω source and a 50 Ω load. Each port has a series inductor and a shunt capacitor on the 50 Ω side. Device impedance at the center frequency is a parallel R–C value and is distinct from the 50 Ω system termination.
| Model | Input and output impedance at fC | Series L Each port |
Shunt C 50 Ω side |
Reference temperature |
|---|---|---|---|---|
| FSF-5050-862M5 | 113 Ω ∥ 3.7 pF | 12 nH | 5 pF | Not specified |
| FSF-5050-868M3 | 117 Ω ∥ 3.7 pF | 15 nH | 3.3 pF | 25 °C |
| FSF-5050-868M69 | 117 Ω ∥ 3.7 pF | 12 nH | 5 pF | 25 °C |
| FSF-5050-868M95 | 117 Ω ∥ 3.7 pF | 12 nH | 5 pF | −45 to +90 °C |
| FSF-5050-869M6 | 117 Ω ∥ 3.7 pF | 12 nH | 5 pF | −45 to +90 °C |
∥ denotes a parallel R–C combination. The impedance and matching-component values above are stated without Min. / Typ. / Max. classification in the datasheet. FSF-5050-868M3 reference response includes matching-circuit loss. Do not extend its 25 °C condition to the other models.
Keep RF traces short, provide effective grounding and evaluate the complete response on the actual PCB. Confirm the rejection mask and other requirements that are not separately tabulated here.
Package & Pin Assignment
5.0 × 5.0 mm, Eight-Terminal SMD
Confirm the maximum package height before PCB release: the datasheet contains both 1.5 mm and 1.7 mm maximum-height references. The product photograph is not a PCB footprint.
| Model | Input | Output | Ground | Case ground |
|---|---|---|---|---|
| FSF-5050-862M5 | 1 in outline / pin table; test circuit labels 2 | 5 | 2, 3, 4, 6, 7, 8 in pin table | Not separately identified |
| FSF-5050-868M3 | 1 in pin table / test circuit | 5 | 2, 3, 6, 7 in pin table | 4, 8 |
| FSF-5050-868M69 / 868M95 / 869M6 | 1 | 5 | 2, 3, 6, 7 | 4, 8 |
For FSF-5050-862M5, resolve the input-pin difference before wiring; the ground list shown follows the pin table only. For FSF-5050-868M3, the outline also allows pin 2 as input with pin 1 grounded. Use the confirmed configuration for the selected part rather than combining alternative assignments.
Selection and Design-In Support
Confirm the Complete Specification
Send FCom the selected model, wanted signal range, bandwidth definition, insertion-loss limit, rejection mask, source and load requirements, temperature range, sample quantity and expected usage. Confirm package height, pin assignment and the complete ordering code before release.
Explore the Series
Related FSF-5050 SAW Filters
Explore four other FSF-5050 frequency options. Check each model’s bandwidth, matching network, temperature limits and pin configuration for your design; these links do not imply interchangeability.
Engineering Questions
Frequently Asked Questions
Does 862.5–869.6 MHz describe one continuous passband?
No. This page covers five separate models centered at 862.5, 868.3, 868.69, 868.95 and 869.6 MHz. Choose the model using its own electrical specifications and matching requirements.
How is the 3 dB bandwidth defined?
BW3 is measured relative to the minimum insertion loss, ILmin. It is separate from the frequency interval stated for ILmin. FSF-5050-862M5 specifies 1.00 MHz minimum and 1.70 MHz typical BW3; the other models list typical BW3 only.
Can all five models use the same matching network?
No. Each port uses a series inductor and a shunt capacitor on the 50-ohm side. FSF-5050-868M3 uses 15 nH and 3.3 pF per port; the other four models use 12 nH and 5 pF per port. Validate performance on the actual PCB.
What must be confirmed before PCB layout?
Confirm the maximum package height and input-pin configuration. The datasheet contains both 1.5 mm and 1.7 mm maximum-height references. FSF-5050-862M5 has an input-pin difference between the outline and test circuit; FSF-5050-868M3 includes an alternate input-pin option. Use the confirmed drawing for the selected model.