FSF-5050 Series · RF Bandpass Filter

916.3 MHz SAW Bandpass Filter

FSF-5050-916M3

Narrowband UHF signal selection for receiver preselection and RF test paths. Evaluate the 1.1 MHz typical 3 dB bandwidth with the specified external matching network.

  • 5.0 × 5.0 mm SMD
  • 8-pad, no-lead package
  • −40 to +85 °C operation
FCom FSF-5050-916M3 916.3 MHz SAW filter, with the marked top face on the left and bottom solder pads on the right
FSF-5050-916M3 · Top view (left), bottom view (right).

Key Features

Define the Passband. Check the Interface.

Center Frequency

916.3 MHz

Typical center frequency for narrowband UHF filtering.

3 dB Bandwidth

1.1 MHz typ.

Use the stated 3 dB criterion; minimum and maximum bandwidth limits are not listed.

Minimum Insertion Loss

5.0 dB typ.

6.0 dB maximum for ILmin. Allow for filter loss and matching in the receiver gain budget.

The bandwidth value follows the FCom electrical table. Confirm the applicable specification and full ordering code for your design; typical values are not guaranteed limits.

FSF-5050-916M3 Datasheet (PDF)

Electrical Specifications

Six Key Selection Parameters

Reference values for the listed FCom model. The operating range does not establish a measurement temperature or guarantee every typical value across that range.

Scroll horizontally to view all columns.

FSF-5050-916M3 · Electrical and Temperature Data
Parameter Min. Typ. Max. Unit Definition / condition
Center frequency, fc — 916.3 — MHz Typical value in the electrical table
3 dB bandwidth — 1.1 — MHz 3 dB criterion
Minimum insertion loss, ILmin — 5.0 6.0 dB Minimum loss; not a whole-passband loss limit
Amplitude ripple — — — dB Not specified
Operating temperature −40 — +85 °C Operating range
Storage temperature −40 — +85 °C Storage range

“—” means no value is specified, not zero. Test terminations: 50 Ω source and 50 Ω load, with external matching at both ports. Device input/output impedance and electrical measurement temperature are not specified in the supplied FCom sheet. Refer to the datasheet for the complete supplied information.

Typical Applications

Narrowband Filtering at 916.3 MHz

Receiver Preselection

Evaluate the filter in a receiver RF path requiring selection near 916.3 MHz. Check wanted-signal bandwidth, matching and the front-end loss budget.

UHF Signal Selection

Select a narrow RF band for downstream processing. Confirm the required usable passband and rejection limits under the intended operating conditions.

RF Test & Measurement

Evaluate frequency-selective filtering in a 916.3 MHz test path, using defined source/load terminations and measurement reference planes.

Integration Notes

Use the Specified Matching Conditions

Port Matching

The test network uses a series 18 nH inductor at each port and a shunt 4 pF capacitor on each test-port side. Source and load terminations are 50 Ω.

Component Selection

The FCom sheet references Coilcraft CS series 0805 inductors and Murata GRM series 0402 capacitors. Evaluate actual components and PCB parasitics when implementing the network.

Board Evaluation

Confirm source/load requirements, grounding, pad orientation and the usable passband on the target PCB. A shared package size does not establish electrical interchangeability.

50 Ω describes the matched test environment. It does not specify the device’s bare-port impedance or establish direct 50 Ω connection without matching.

Package & Pin Assignment

5.0 × 5.0 mm, Eight-Pad SMD Package

FSF-5050-916M3 uses the listed eight-pad, no-lead package. Pin functions below follow the supplied FCom sheet.

Confirm maximum height before layout release. The supplied sheet retains a 1.5 mm maximum-height template and identifies a 1.7 mm reference height. The applicable maximum height and PCB land pattern require confirmation.

Verify drawing orientation and pad numbering before PCB release. For other pin configurations, contact FCom.

FSF-5050-916M3 · Pin Functions
Pin Function
2Input
6Output
1Input ground
5Output ground
3, 4, 7, 8Ground

Selection and Design-In Support

Bring Your RF Requirements to FCom

Share the required bandwidth and dB criterion, source/load requirements, operating temperature and application. Include sample quantity and estimated annual volume, and ask FCom to confirm the applicable specification, mechanical drawing and complete ordering code.

Identify any bandwidth tolerance, ripple, rejection or mechanical-clearance requirement that needs explicit agreement.

Engineering Questions

Frequently Asked Questions

Is the bandwidth 1.1 MHz or 1.2 MHz?

The applicable FCom electrical table lists a typical 3 dB bandwidth of 1.1 MHz. The reference document cover uses 1.2 MHz. Use 1.1 MHz for initial selection and confirm the required bandwidth limits with FCom; a guaranteed minimum bandwidth is not listed.

Can I connect the filter directly to a 50 Ω signal path?

The stated 50 Ω values describe the source and load of the matched test circuit. Each port uses a series 18 nH inductor and a shunt 4 pF capacitor on the test-port side. The device input and output impedances are not specified, so direct 50 Ω compatibility is not established.

Does 6.0 dB describe insertion loss across the entire passband?

No. The listed parameter is minimum insertion loss, ILmin: 5.0 dB typical and 6.0 dB maximum. It does not define worst-case loss at every passband frequency. Amplitude ripple is not specified; confirm the usable passband and loss budget for your signal.

Which pins are input, output and ground?

The FCom pin table identifies pin 2 as input and pin 6 as output. Pin 1 is input ground, pin 5 is output ground, and pins 3, 4, 7 and 8 are ground. Confirm pad numbering and viewing direction against the applicable package drawing before PCB release.

What package height should I use for mechanical design?

The package footprint is 5.0 × 5.0 mm with eight no-lead SMD pads. The supplied FCom sheet retains a 1.5 mm maximum-height template and notes a 1.7 mm reference height. Confirm the applicable maximum height and land pattern with FCom before finalizing mechanical clearance or PCB layout.

What should I include in an inquiry?

Include FSF-5050-916M3, the application, required bandwidth and dB criterion, source and load requirements, operating temperature, sample quantity and estimated annual volume. Confirm the applicable specification and complete ordering code with FCom.

Downloads

Datasheets, mechanical drawings, and supporting documents.

Need this product?

Tell us your selected model, required passband, source/load requirements, operating temperature, sample quantity and expected volume. Contact our team to discuss the next steps.

Contact Us Anytime

Drag & Drop Files, Choose Files to Upload

Contact Us Anytime

Drag & Drop Files, Choose Files to Upload