FSF-5050 Series · SAW Bandpass Filters

611, 616.25 & 618.25 MHz SAW Bandpass Filters

FSF-5050-611M / 616M25 / 618M25

Three frequency options for UHF receiver filtering and preselection, in a 5.0 × 5.0 mm, 8-pad SMD package. Select by center frequency, bandwidth definition and operating temperature.

  • 5.0 × 5.0 mm SMD
  • 8-terminal, no-lead package
  • Model-specific temperature ranges
FCom FSF-5050 SAW filters: 611 MHz top, 616.25 MHz middle and 618.25 MHz bottom; marked lids on the left and eight-pad undersides on the right
Top: 611 MHz · Middle: 616.25 MHz · Bottom: 618.25 MHz. Left: marked lid · Right: pad side.

Model Selection

Choose the Frequency and Specification You Need

The combined FCom datasheet covers 611 MHz on page 1, 616.25 MHz on page 2 and 618.25 MHz on page 3. Bandwidth definitions and temperature ranges differ; compare each model with its own conditions.

Combined FCom datasheet · Page 1

FSF-5050-611M

611 MHz

Typical center frequency. Uses a 3 dB bandwidth definition and ILmin.

3 dB bandwidth
7.0 MHz min. / 9.8 MHz typ.
ILmin
2.3 dB typ. / 2.6 dB max.
Operating temperature
−20 to +70 °C

ILmin is the minimum passband attenuation; the 3 dB bandwidth is measured relative to ILmin.

Combined FCom datasheet · Page 2

FSF-5050-616M25

616.25 MHz

Typical center frequency. Uses a 2 dB bandwidth definition and center-frequency loss.

2 dB bandwidth
2.5 MHz min. / 8.0 MHz typ.
Loss at 616.25 MHz
2.3 dB typ. / 3.5 dB max.
Operating temperature
0 to +50 °C

Insertion loss is specified at the center frequency, not across the full 2 dB bandwidth.

Combined FCom datasheet · Page 3

FSF-5050-618M25

618.25 MHz

Typical center frequency. Uses a 2 dB bandwidth definition and center-frequency loss.

2 dB bandwidth
2.5 MHz min. / 8.0 MHz typ.
Loss at 618.25 MHz
2.4 dB typ. / 3.5 dB max.
Operating temperature
0 to +50 °C

Insertion loss is specified at the center frequency, not across the full 2 dB bandwidth.

Compare definitions before numbers. A 3 dB bandwidth is not equivalent to a 2 dB bandwidth. The 611 MHz ILmin value also uses a different definition from the center-frequency loss of the other models. A shared package does not establish electrical interchangeability.

Electrical Specifications

Six Key Parameters, Model by Model

Each model has six key specifications below. Typical values are for design guidance; confirm applicable production limits before release. A dash (—) means not specified or not applicable in that column, not zero.

Scroll horizontally to view all columns.

FSF-5050-611M · 611 MHz

FSF-5050-611M · Six Key Specifications
Parameter Min. Typ. Max. Unit Definition / condition
Center frequency — 611 — MHz Typical value
Insertion loss (ILmin) — 2.3 2.6 dB Minimum passband attenuation
3 dB bandwidth 7.0 9.8 — MHz Relative to ILmin
Amplitude ripple — 0.4 1.3 dB Over 609.5–612.5 MHz
Operating temperature −20 — +70 °C Operating limits
Storage temperature −40 — +85 °C Storage limits

ILmin is the minimum passband attenuation. The 3 dB bandwidth is measured relative to ILmin. Test source / load: 50 Ω / 50 Ω with direct connections. Device impedances and measurement temperature are not specified in the supplied FCom table.

FSF-5050-616M25 · 616.25 MHz

FSF-5050-616M25 · Six Key Specifications
Parameter Min. Typ. Max. Unit Definition / condition
Center frequency — 616.25 — MHz Typical value
Insertion loss at Fc — 2.3 3.5 dB At 616.25 MHz
2 dB bandwidth 2.5 8.0 — MHz 2 dB bandwidth
Amplitude ripple — 0.3 1.5 dB Over 615–617.5 MHz
Operating temperature 0 — +50 °C Operating limits
Storage temperature −40 — +85 °C Storage limits

Insertion loss is specified at 616.25 MHz, not across the entire 615–617.5 MHz ripple interval. Test source / load: 50 Ω / 50 Ω with direct connections. Device impedances and measurement temperature are not specified in the supplied FCom table.

FSF-5050-618M25 · 618.25 MHz

FSF-5050-618M25 · Six Key Specifications
Parameter Min. Typ. Max. Unit Definition / condition
Center frequency — 618.25 — MHz Typical value
Insertion loss at Fc — 2.4 3.5 dB At 618.25 MHz
2 dB bandwidth 2.5 8.0 — MHz 2 dB bandwidth
Amplitude ripple — 0.2 1.5 dB Over 617–619.5 MHz
Operating temperature 0 — +50 °C Operating limits
Storage temperature −40 — +85 °C Storage limits

Insertion loss is specified at 618.25 MHz, not across the entire 617–619.5 MHz ripple interval. Test source / load: 50 Ω / 50 Ω with direct connections. Device impedances and measurement temperature are not specified in the supplied FCom table.

Typical Applications

UHF Filtering Around the Selected Center Frequency

UHF Receiver Filtering

Select the 611, 616.25 or 618.25 MHz model for the intended receiver frequency, then evaluate bandwidth, loss and ripple against the circuit requirements.

Receiver Preselection

Provide frequency-selective filtering ahead of a receiver stage. Confirm the required rejection and interface behavior in the actual system.

Test and Measurement

Use the appropriate frequency option for filtering in measurement signal chains, retaining the model-specific loss definition and ripple interval during evaluation.

Integration Notes

Keep Each Model’s Conditions Separate

Test Terminations and Device Impedance

The supplied FCom pages specify direct connections with 50 Ω source and load test terminations for all three models. These are evaluation conditions, not specified device impedances. Assess the actual source, load and PCB parasitics before deciding whether matching is required.

Bandwidth and Loss Definitions

For 611 MHz, retain ILmin and its relative 3 dB bandwidth definition. For 616.25 and 618.25 MHz, keep center-frequency loss separate from ripple over a band. Do not compare 3 dB bandwidth to 2 dB bandwidth directly.

Operating Temperature

Check the operating range: −20 °C to +70 °C for 611 MHz; 0 °C to +50 °C for the other two models. Storage limits do not extend the operating range.

Pin Labels

Follow the model-specific signal-pin labels in the table below and verify pad orientation against the applicable FCom drawing. A shared package does not establish pin compatibility across models.

Package & Pin Assignment

5 × 5 mm, 8-Pad SMD Package — Model-Specific Pins

All three supplied FCom pages specify a 5.0 × 5.0 mm, 8-SMD package with a maximum height of 1.5 mm. Signal-pin labels differ, so use the column for the selected model.

Body dimensions
5.0 × 5.0 mm
Maximum height
1.5 mm
Package type
8-SMD, no lead

The table preserves the FCom labels; Input/Output does not establish verified bidirectional equivalence. Product photographs identify the lid and pad sides and are not footprint drawings. Consult the applicable PDF page before layout release; contact FCom for other pin configurations.

FCom Pin Functions · Read by Model
Pad(s) FSF-5050-611M FSF-5050-616M25 FSF-5050-618M25
2 Input/Output Input Input
6 Input/Output Output Output
1, 3, 5, 7 Ground Ground Ground
4, 8 Case ground Case ground Case ground

Selection and Design-In Support

Define the Frequency, Bandwidth and Conditions Together

Share the selected model, center frequency, required bandwidth and its dB definition, source and load requirements, operating temperature, sample quantity and estimated usage. Include package or pin constraints that could affect compatibility.

The displayed model names are not confirmed complete ordering codes. Confirm the ordering configuration and applicable specifications with FCom before ordering.

Engineering Questions

Frequently Asked Questions

Which model should I select?

Start with the required frequency: 611, 616.25 or 618.25 MHz. Then check the bandwidth definition and temperature range. The 611 MHz model uses a 3 dB bandwidth and operates from −20 °C to +70 °C; the 616.25 and 618.25 MHz models use 2 dB bandwidths and operate from 0 °C to +50 °C.

What does ILmin mean for the 611 MHz model?

ILmin is the minimum passband attenuation, with a typical value of 2.3 dB and a maximum of 2.6 dB in the supplied FCom datasheet. Its 3 dB bandwidth is measured relative to ILmin. This loss definition must not be relabeled as insertion loss at the center frequency or as a maximum loss across the ripple band.

Are the bandwidth and ripple figures directly comparable?

The 611 MHz model specifies a 3 dB bandwidth of 7.0 MHz minimum and 9.8 MHz typical. The other two models specify 2 dB bandwidths of 2.5 MHz minimum and 8.0 MHz typical. Ripple is measured over a different stated interval for each model. Compare values only when their definitions and conditions match.

Does direct testing with 50 Ω terminations mean matching is unnecessary?

No. The supplied FCom pages specify direct connections with 50 Ω source and load test terminations. They do not specify the device input or output impedance. Assess the actual source, load and PCB before deciding whether matching is needed.

Do all three models have the same signal-pin labels?

No. FSF-5050-611M labels pads 2 and 6 as Input/Output. FSF-5050-616M25 and FSF-5050-618M25 label pad 2 as Input and pad 6 as Output. All three list pads 1, 3, 5 and 7 as ground, and pads 4 and 8 as case ground. Confirm orientation using the applicable FCom drawing.

Which PDF page and inquiry details apply to my model?

The combined FCom datasheet covers FSF-5050-611M on page 1, FSF-5050-616M25 on page 2 and FSF-5050-618M25 on page 3. Include the selected model, frequency, bandwidth definition, source and load requirements, temperature range, sample quantity and estimated usage in your inquiry. Confirm the complete ordering code with FCom.

Downloads

Datasheets, mechanical drawings, and supporting documents.

Need this product?

Tell us your selected model, required passband, source/load requirements, operating temperature, sample quantity and expected volume. Contact our team to discuss the next steps.

Contact Us Anytime

Drag & Drop Files, Choose Files to Upload

Contact Us Anytime

Drag & Drop Files, Choose Files to Upload