FSF-5050 Series · SAW Bandpass Filter

584 MHz SAW Bandpass Filter

FSF-5050-584M

RF/IF signal selection across a specified 578–590 MHz passband in a 5.0 × 5.0 mm, 8-pad SMD package. Typical insertion loss is 1.6 dB, with a 4.5 dB maximum over the specified passband.

  • 5.0 × 5.0 mm SMD
  • 8-terminal, no-lead package
  • −20 to +75 °C operation
FCom FSF-5050-584M 584 MHz SAW filter, marked lid on the left and eight-pad underside on the right
FSF-5050-584M · Marked lid and pad-side views.

Key Features

Key Selection Points

Specified Passband

578–590 MHz

Insertion loss and amplitude ripple are specified across this interval. The 3 dB bandwidth is not provided.

Passband Ripple

0.7 dB typ.

2.0 dB maximum amplitude ripple across 578–590 MHz.

Test Terminations

50 Ω / 50 Ω

Source / load test conditions. Device input and output impedances are not specified.

The specified passband 578–590 MHz is a frequency range, not the 3 dB bandwidth. A 3 dB bandwidth is not specified in the supplied datasheet.

Electrical Specifications

Six Key Selection Parameters

Key values for FSF-5050-584M from the supplied FCom datasheet. Typical values are for design guidance; confirm applicable production limits before design release.

Scroll horizontally to view all columns.

FSF-5050-584M · Six Key Specifications
Parameter Min. Typ. Max. Unit Definition / condition
Center frequency — 584 — MHz Typical value
Specified passband — — — MHz 578–590 MHz; not a 3 dB bandwidth
Insertion loss — 1.6 4.5 dB Over 578–590 MHz
Amplitude ripple — 0.7 2.0 dB Over 578–590 MHz
3 dB bandwidth — — — MHz Not specified
Operating temperature −20 — +75 °C Operating limits; measurement temperature not stated

— means not specified or not applicable in that column; it does not mean zero. The supplied FCom table does not state a measurement temperature. Storage temperature: −40 °C to +85 °C. The specified 578–590 MHz interval must not be described as a 12 MHz 3 dB bandwidth. Refer to the FCom datasheet for the supplied specification and package detail.

Typical Applications

RF/IF Signal Selection Around 584 MHz

584 MHz RF/IF Receivers

Passband selection in receiver stages operating around 584 MHz, subject to the required loss and ripple budget.

UHF Receiver Front Ends

Frequency-selective filtering for wanted signals in the specified passband. Check system-level rejection and interface requirements during evaluation.

Test and Measurement

Band selection in measurement signal chains that use the 578–590 MHz interval. Evaluate the filter within the intended measurement setup.

Integration Notes

Reproduce the Relevant Test Conditions

Source and Load

The reference measurement uses a single-ended source and load, each terminated in 50 Ω. These are test conditions and do not establish the device’s own input or output impedance.

Matching and Layout

Assess the required matching with the actual source, load and PCB parasitics; no matching-component values are provided in the FCom attachment.

Frequency and Temperature Evaluation

Verify performance across the intended operating temperature and frequency range. The same center frequency alone does not establish drop-in compatibility.

Release Checks

Confirm passband definition, insertion loss and ripple limits, interface and pin assignment, package height and the required operating temperature before qualification.

Package & Pin Assignment

5 × 5 mm, 8-Pad SMD Package

The supplied FCom drawing specifies a maximum height of 1.5 mm. The product photograph shows the marked lid and the eight-pad underside.

Body dimensions
5.0 × 5.0 mm
Maximum height
1.5 mm
Package type
8-SMD, no lead

Use the mechanical drawing in the FCom datasheet to confirm dimensions and pad orientation before layout release. The photograph is not a footprint drawing. Contact FCom for other pin configurations.

FSF-5050-584M · Pin Functions
Pad(s) Function
2Input/Output
6Input/Output
1, 3, 5, 7Ground
4, 8Case ground

Selection and Design-In Support

Define the Passband, Loss and Interface Together

Discuss FSF-5050-584M with FCom using your required passband, bandwidth definition, source and load requirements, temperature range, sample quantity and estimated usage. Include any package or pin constraints to support a meaningful compatibility review.

FSF-5050-584M is the model designation shown in the supplied datasheet. Confirm the complete ordering code before placing an order.

Engineering Questions

Frequently Asked Questions

Is 578–590 MHz the 3 dB bandwidth?

No. It is the specified passband used for insertion loss and amplitude ripple. A 3 dB bandwidth is not specified in the supplied FCom datasheet.

Does the 50 Ω test setup define the device impedance?

No. The source and load are each terminated in 50 Ω for testing. Device input and output impedances are not specified; assess matching with the intended RF interface.

Which pads carry the signal?

The FCom pin table identifies pads 2 and 6 as Input/Output, pads 1, 3, 5 and 7 as ground, and pads 4 and 8 as case ground. Confirm footprint orientation against the applicable mechanical drawing before layout release.

What temperature range applies?

The specified operating range is −20 °C to +75 °C. Storage is specified separately as −40 °C to +85 °C. The supplied FCom table does not state a measurement temperature.

Can this model directly replace another 584 MHz filter?

Frequency alone does not establish interchangeability. Compare the passband definition, loss and ripple limits, interface and matching, pin assignment, package height and operating temperature before qualification.

What should I include in a technical inquiry?

Include FSF-5050-584M, the required passband and bandwidth definition, source and load requirements, operating temperature, sample quantity and estimated usage. Confirm the complete ordering code with FCom before ordering.

Downloads

Datasheets, mechanical drawings, and supporting documents.

Need this product?

Tell us your selected model, required passband, source/load requirements, operating temperature, sample quantity and expected volume. Contact our team to discuss the next steps.

Contact Us Anytime

Drag & Drop Files, Choose Files to Upload

Contact Us Anytime