Low-phase-noise clocks for Ethernet and network equipment
FCO-3L-UJ Low-Jitter Differential Crystal Oscillator
100 / 125 / 156.25 MHz options · 3225 six-pad SMD
The FCO-3L-UJ is a compact differential quartz oscillator for compatible 40G / 100G Ethernet, network equipment and test instrumentation. At 156.25 MHz and 3.3 V, its LVDS and LVPECL configurations specify 100 fs maximum RMS phase jitter, integrated from 12 kHz to 20 MHz.
- 3225 · 3.2 × 2.5 mm nominal
- LVDS / LVPECL / HCSL
- ±50 ppm · −40 to +105°C option
Body: 3.20 × 2.50 × 0.90 mm, each ±0.15 mm.
Use the mechanical drawing for footprint design.
FCO-3L-UJ uses fundamental-mode quartz oscillation to support low source phase noise. Frequency coverage depends on the output interface: 100–175 MHz for LVDS, 100–220 MHz for LVPECL and 100–135 MHz for HCSL. Standard HCSL frequencies are 100 MHz and 125 MHz. Select the reference frequency, output levels and clock-noise limits together with the receiver requirements.
Key Features
A 3225 differential reference-clock platform combining low integrated jitter, three output interfaces and stability grades matched to the operating-temperature range.
Low RMS phase jitter
50 fs typ.
Typical RMS phase jitter is listed as 0.05 ps, equivalent to 50 fs, integrated from 12 kHz to 20 MHz.
LVDS/LVPECL specify 100 fs maximum at 156.25 MHz and 3.3 V. The 1.8 V LVDS column lists 300 fs maximum; confirm its test conditions at selection.
Frequency stability options
±50 ppm max.
Overall stability grade available over −40 to +105°C. Recommended parts on this page use the ±50 ppm grade.
Additional options include ±25 ppm over −40 to +85°C and ±20 ppm over −20 to +70°C.
Compact differential interface
3.2 × 2.5 mm nom.
3225 six-pad SMD package with complementary outputs and tri-state enable/disable control.
LVDS and HCSL supplies: 1.8 / 2.5 / 3.3 V. LVPECL supplies: 2.5 / 3.3 V.
Typical Applications
Recommended FCom part numbers for compatible Ethernet, networking, HCSL and instrumentation clock inputs. All listed parts use a 3.3 V supply and ±50 ppm overall stability. Differences in frequency, output interface or temperature range are shown after each part number.
40G / 100G Ethernet and Optical Modules
A 156.25 MHz differential reference for compatible Ethernet PHY, SerDes and optical-module clock inputs. Select LVDS or LVPECL to match the receiver, with the temperature grade chosen for conditions at the oscillator location.
Recommend Parts
Design consideration. At 156.25 MHz and 3.3 V, LVDS and LVPECL specify 100 fs maximum RMS jitter over 12 kHz–20 MHz. Confirm that this limit and ±50 ppm stability meet the receiver budget. Supply current is 35 mA maximum for LVDS and 65 mA maximum for LVPECL.
Switch, Router and FPGA Reference Clocks
Fixed-frequency references for compatible switch ASICs, routers, FPGA transceivers and clock-distribution inputs. The options below use LVDS output and the −40 to +105°C temperature grade; select the frequency required by the receiving device.
Recommend Parts
Design consideration. The specified LVDS load is 100 Ω across the differential outputs. Review input swing, common-mode range and coupling, and include buffer or synthesizer noise in the system clock budget. Confirm jitter limits at the selected reference frequency.
100 MHz HCSL Reference Clocks
A 100 MHz HCSL option for evaluating compatible PCIe reference-clock trees and other HCSL inputs. The recommended 3.3 V parts have a 46 mA maximum supply current and a specified load of 50 Ω from each output to ground.
Design consideration. The HCSL table specifies 100 fs maximum RMS jitter at 3.3 V over 12 kHz–20 MHz. PCIe qualification requires the applicable clock architecture, generation-specific jitter filtering and electrical tests; broadband RMS jitter alone does not establish compliance.
Test and Measurement Platforms
A differential reference for communication test equipment, evaluation boards and clock-path characterization. The parts below share the −40 to +85°C temperature grade and provide 100 MHz LVDS or 156.25 MHz LVDS/LVPECL options.
Recommend Parts
Design consideration. At 156.25 MHz and 3.3 V, the LVDS/LVPECL tables list typical phase noise of −150 dBc/Hz at 10 kHz offset, −155 dBc/Hz at 100 kHz and −160 dBc/Hz at 1 MHz. Compare measurements under consistent supply, load, temperature and bandwidth conditions.
Select a recommended part number to request pricing, samples or technical support. For other supply-voltage requirements, including 1.8 V or 2.5 V LVDS/HCSL and 2.5 V LVPECL options, please contact our sales team.
Frequently Asked Questions
Which frequencies and output interfaces are available?
LVDS covers 100–175 MHz and LVPECL covers 100–220 MHz; both list standard fixed frequencies of 100 MHz, 125 MHz and 156.25 MHz. HCSL covers 100–135 MHz, with standard frequencies of 100 MHz and 125 MHz.
Each ordered part has one specified output frequency. Contact FCom for other frequencies within the applicable interface range. Frequency availability and performance are reviewed for the selected output and supply configuration.
How should the 50 fs and 100 fs jitter values be interpreted?
The datasheet feature summary identifies 0.05 ps, equivalent to 50 fs, typical RMS phase jitter over 12 kHz–20 MHz. The LVDS and LVPECL electrical tables specify a maximum of 0.1 ps, equivalent to 100 fs, at 156.25 MHz, with a 3.3 V measurement note. A typical value is not a guaranteed maximum.
The HCSL jitter row separately specifies 0.1 ps, equivalent to 100 fs, maximum with a 3.3 V measurement note and the same integration bandwidth. Its test frequency is not identified in that row; confirm the qualification conditions for the selected HCSL part.
For LVDS/LVPECL at frequencies other than 156.25 MHz, confirm the applicable jitter limit. The published test environment is 25 ±5°C and 40–70% relative humidity.
Which parts are recommended for compatible 40G / 100G Ethernet inputs?
For a receiver requiring 156.25 MHz LVDS, FCO3L33DFYUJ-156.25MHz specifies 3.3 V, ±50 ppm overall stability and −40 to +85°C. FCO3L33DFUUJ-156.25MHz extends the temperature range to −40 to +105°C. FCO3L33PFUUJ-156.25MHz provides LVPECL at the same extended temperature grade.
Final selection follows the receiver’s reference frequency, permitted frequency error, electrical levels and clock-noise requirements. Ethernet line rate alone does not determine the oscillator configuration.
How should stability and temperature grades be selected?
Recommended parts use ±50 ppm overall stability, code F, with −40 to +85°C, code Y, or −40 to +105°C, code U. Other listed options include ±25 ppm over −40 to +85°C and ±20 ppm over −20 to +70°C.
The ±20 ppm option over −40 to +85°C is conditional. The ±20 ppm and ±25 ppm grades are not available over −40 to +105°C or −40 to +125°C. The ±50 ppm grade over −40 to +125°C is conditional and requires configuration review.
Overall stability includes calibration at 25°C, operating-temperature range, input-voltage variation, load variation, first-year aging, shock and vibration. The separate first-year aging specification is ±3 ppm at 25°C.
Which supply options, current limits and voltage-dependent jitter values apply?
LVDS and HCSL support nominal supplies of 1.8 V, 2.5 V or 3.3 V. LVPECL supports 2.5 V or 3.3 V. These are separate ordering options.
LVDS supply current is 35 mA maximum at 2.5 V or 3.3 V, and 25 mA maximum at 1.8 V. LVPECL is specified at 65 mA maximum, and HCSL at 46 mA maximum, at their supported nominal supplies.
The 1.8 V LVDS column lists 0.3 ps, equivalent to 300 fs, maximum RMS jitter at 156.25 MHz. The 2.5 V and 3.3 V columns list 0.1 ps, equivalent to 100 fs. Because the common jitter measurement note identifies 3.3 V, confirm the approved test conditions for lower-voltage configurations. Contact our sales team for other voltage requirements.
What are the start-up, standby and enable specifications?
The series specifies a maximum start-up time of 5 ms, a maximum standby current of 30 µA and a 45–55% duty cycle. The tri-state control thresholds are VIH ≥0.7 × VDD for enable and VIL ≤0.3 × VDD for disable. Use the approved pin assignment for the ordered configuration when designing the control connection.
What output termination and supply decoupling are required?
The specified LVDS load is 100 Ω across OUT and OUTN. LVPECL uses 50 Ω from each output to VDD − 2 V; HCSL uses 50 Ω from each output to ground. The final coupling and termination network must satisfy the receiver’s input swing and common-mode requirements.
Place a 0.1 µF bypass capacitor as close as possible to the oscillator between VDD and ground. Route the complementary outputs as a controlled differential pair and evaluate noise at the receiving clock input.
What are the package dimensions?
FCO-3L-UJ uses a nominal 3225, 3.2 × 2.5 mm, six-pad SMD package. The datasheet mechanical drawing specifies 3.20 ±0.15 mm length, 2.50 ±0.15 mm width and 0.90 ±0.15 mm height. Use the approved drawing, pad orientation and land pattern for PCB footprint design.